- 摘 要
-
(廣東省建筑設(shè)計(jì)研究院,廣州510010)
[提要]武漢光谷中心花園辦公樓在施工期間發(fā)生火災(zāi),剛澆搗3d的樓面上所立的模板被燒毀?;馂?zāi)后過火樓面產(chǎn)生了廣泛分布的裂縫,造成過火樓面一定程度損傷,但混凝土強(qiáng)度等級(jí)仍能滿足設(shè)計(jì)要求。根據(jù)火災(zāi)后的檢測鑒定結(jié)果,對(duì)該樓面采取另配板面筋、加厚樓板方式加固,取得了良好效果。
[關(guān)鍵詞]施工火災(zāi);樓面加固;混凝土結(jié)構(gòu)
Reinforcing and Retrofitting of an Office Building in Wuhan Optical Valley After Fire Accident/Zhang Lianguang,Dong Xiaoming,Xu Jia(The Architectural Design and Research Institute of Guangdong Province,Guangzhou 510010,China)Abstract:The fire accident of office building in Wuhan Optical Valley in construction caused the timber moulding board burnt out which was erected on the concrete floor newly cast 3 days before. Although cracks were extensively distributed on the floor and some damage occurred,the test result showed that concrete strength still met the design requirement.According to the test report,such retrofitting measures as adding steels,thickening the floor are adopted,and satisfaction effect was achieved.
Keywords:construction; fire accident; floor retrofitting; RC structure
- 下載地址
-
你還沒注冊(cè)?或者沒有登錄?這篇論文要求至少是本站的注冊(cè)會(huì)員才能閱讀!
如果你還沒注冊(cè),請(qǐng)趕緊點(diǎn)此注冊(cè)吧!
如果你已經(jīng)注冊(cè)但還沒登錄,請(qǐng)趕緊點(diǎn)此登錄吧!