- 摘 要
-
楊 鴻, 馬臣杰, 張良平
(深圳華森建筑與工程設(shè)計(jì)顧問(wèn)有限公司,深圳518054)[摘要] 以南京青奧中心.會(huì)議中心項(xiàng)目為背景,用MIDAS Gen建立了其三維非線性結(jié)構(gòu)整體分析模型。在以抗震性能為基準(zhǔn)的設(shè)計(jì)思想和以位移為基準(zhǔn)的抗震設(shè)計(jì)方法的指導(dǎo)下,對(duì)彈性樓板及弱化的彈性樓板整體結(jié)構(gòu)進(jìn)行了大震動(dòng)力彈塑性時(shí)程分析。結(jié)構(gòu)的位移以及塑性鉸的分布情況等結(jié)果表明,會(huì)議中心的整體抗震性能較好,滿(mǎn)足大震作用下結(jié)構(gòu)的抗震性能目標(biāo)。
[關(guān)鍵詞] 復(fù)雜空間結(jié)構(gòu);大震;動(dòng)力彈塑性時(shí)程分析
中圖分類(lèi)號(hào):TU313 文獻(xiàn)標(biāo)識(shí)碼:A 文章編號(hào):1002-848X(2012) S2-0116-04Dynamic elastic-plastic time history analysis of Nanjing Youth Olympic Center-Conference Center
Yang Hong, Ma Chenjie, Zhang Liangping
( Huasen Arclutecture & Engineering Design Consultants Ltd., Shenzhen 518054, China)Abstract: This paper takes the project of Nanjing Youth Olympic Center-Conference Center as the background, and uses MIDAS Gen to establish the three-dimensional nonlinear structure analysis model. Under the guidance of design thought based on the seismic performance and seismic design method based on the displacement, the dynamic elastic-plastic time history analysis of the whole structure of elastic floor, and a weakening elastic floor respectively under a large earthquake was camed out. The structure displacement and plastic hinge distribution show that the overall seisnuc performance of the conference center is good, which satisfies the structure seismic performance objectives of the large earthquake.
Keywords: complex spatial structure; large earthquake; dynanuc elastic-plastic time history analysis
- 下載地址
-