884aa四虎影成人精品,99久久国产综合精品女图图等你,97在线观看永久免费视频,久久精品国产精品亚洲38,ⅵdeodesetv性欧美

您現(xiàn)在的位置:建筑結(jié)構(gòu)>> 期 刊>> 2013年>> 第01期>>正文內(nèi)容
磚混教學(xué)樓縱向窗間墻抗震性能試驗研究*
吳昊1,趙世春1,許滸1,張蓬勃1,吳剛2
摘 要
吳昊1,趙世春1,許滸1,張蓬勃1,吳剛2
(1 西南交通大學(xué)土木工程學(xué)院,成都 610031;2 東南大學(xué)混凝土及預(yù)應(yīng)力混凝土結(jié)構(gòu)教育部重點實驗室,南京 210096)
 
[摘要]通過5片磚混教學(xué)樓縱向窗間墻試件的擬靜力試驗,分別對配置不同尺寸和不同配筋率構(gòu)造柱的窗間墻試件的破壞形態(tài)、滯回性能、變形能力等進行了試驗分析。研究結(jié)果表明,構(gòu)造柱的尺寸和配筋率對窗間墻的抗震性能影響較大,增大構(gòu)造柱截面尺寸但保持較低的配筋率可顯著改善窗間墻的抗震性能,但構(gòu)造柱配筋增大到一定程度后反而會降低窗間墻的變形能力。因此,適度增大構(gòu)造柱尺寸并合理控制配筋率是磚混教學(xué)樓縱向窗間墻抗震設(shè)計的關(guān)鍵。
[關(guān)鍵詞]磚混結(jié)構(gòu)教學(xué)樓;窗間墻;構(gòu)造柱;截面尺寸;配筋率
中圖分類號:TU362        文獻標識碼:A        文章編號:1002-848X(2013)01-0081-04
 
Experimental study on the seismic performance of longitudinal wall between windows of brickconcrete school building
Wu Hao1, Zhao Shichun1, Xu Hu1, Zhang Pengbo1, Wu Gang2
(1 School of Civil Engineering, Southwest Jiaotong University, Chengdu 610031, China; 2 Key Laboratory of Concrete and Prestressed Concrete Structures of China Ministry of Education, Southeast University, Nanjing 210096, China)
 
Abstract: Quasi-static tests on five specimens were conducted to investigate the seismic performance of longitudinal wall between windows of brick-concrete school building. The seismic performance of longitudinal wall between windows with different size and reinforcement ratio of structural column was investigated respectively, including damage characteristics, hysteresis behavior and deformation capacity of specimens. The results indicate that the section size and reinforcement ratio of structural column have significant effect on the seismic performance of specimens. Increasing the section size of structural column can improve the seismic performance of longitudinal wall between windows significantly. However, increasing reinforcement ratio of structural column to a certain extent will decrease deformation capacity of longitudinal wall between windows. Therefore, properly increasing the section size of structural column and reasonably controlling the reinforcement ratio are crucial important in the seismic design of longitudinal wall between windows of brick-concrete school building.
Keywords: brick-concrete school building; longitudinal wall between windows; structural column; section size; reinforcement ratio
*國家科技支撐計劃項目(2009BAJ28B01),國家教育部東南大學(xué)博士生國內(nèi)訪學(xué)基金資助項目(BSFX2009-01), 中央高?;究蒲袠I(yè)務(wù)費專項資金資助(SWJTU10XS01)。
作者簡介:吳昊,博士研究生,Email: yong_zhiwu@163.com
 
參考文獻
[1]趙統(tǒng),張新培,田志鵬. 汶川地震中小學(xué)磚混結(jié)構(gòu)教學(xué)樓震害特征分析[J]. 世界地震工程,2009,25(3):150-158.
[2]徐有鄰. 汶川震害的教訓(xùn)——教學(xué)樓倒塌的反思[J]. 建筑結(jié)構(gòu),2009,39(11):50-53.
[3]雷濤,李碧雄,順遠坤,等. 汶川地震中綿竹市中小學(xué)校舍震害調(diào)查分析[J]. 建筑結(jié)構(gòu),2009,39(11):58-62.
[4]李喬,趙世春. 汶川大地震工程震害分析[M]. 成都:西南交通大學(xué)出版社,2008.
[5]清華大學(xué),西南交通大學(xué),重慶大學(xué),等. 汶川地震建筑震害分析及設(shè)計對策[M]. 北京:中國建筑工業(yè)出版社,2009.
[6]孫雪梅,劉偉慶. 大開間約束磚砌體開窗洞墻片的擬靜力試驗研究[J]. 工程抗震,2004(2):31-34.
[7]史慶軒,易文宗,劉伯權(quán).多孔磚砌體開窗洞縱墻片的抗震性能研究[J].世界地震工程,2000,16(2):30-34.
下載地址