- 摘 要
-
江蛟,陶學(xué)康
(中國建筑科學(xué)研究院,北京100013)[摘要] 介紹我國《混凝土結(jié)構(gòu)設(shè)計規(guī)范》GB 50010-2002、美國ACI 318-05規(guī)范、歐洲規(guī)范2及英國規(guī)范BS 8110-1關(guān)于預(yù)應(yīng)力混凝土結(jié)構(gòu)裂縫控制的設(shè)計規(guī)定和構(gòu)造措施;并探討了預(yù)應(yīng)力混凝土裂縫寬度限值對梁底鋼筋最大允許間距的要求,總結(jié)和提出不直接計算裂縫寬度的裂縫控制設(shè)計建議。
[關(guān)鍵詞] 預(yù)應(yīng)力混凝土;裂縫控制;不直接計算;裂縫寬度;構(gòu)造措施Study on control of craclang without direct calculation of crack widths for prestressed concrete
Jiang Jiao, Tao Xuekang
(China Academy of Building Research, Beijing 100013, China)Abstract: The provisions of cracking control and detailing measures for prestressed concrete in Code for design of concrete structures(GB 50010-2002), ACI 318-05, Eurocode 2-Design of concrete structures and British standard BS 8110-1 are introduced, then requirements of limiting values of crack width for the maximum allowable spacing of bars at the bottom of beams for prestressed concrete are studied and the recommended design methods for the control of cracking without direct calculation of crack widths are elaborated.
Keywords: prestressed concrete; control of cracking; without direct calculation; crack widths; detailing measures