- 摘 要
-
曲道鋒1,杜菊紅2
(1 山東省冶金設計院股份有限公司,濟南250101; 2 中建國際設計顧問有限公司,上海200235)[摘要] 結合國內某3000m3以上高爐礦焦槽焦篩結構層現場試車的振動參數值,對焦篩結構層的振動特征進行了分析與研究,并對加固方案進行了比較、選擇;同時對結構層的抗振要求及構造措施進行了探討。
[關鍵詞] 焦槽焦篩;梁板振動;擾力;減振加固Vibration reduction and strengthening on structure layer of coke house vibrating screen in blast furnace
Qu Daofeng1, Du Juhong2
(1 Shandong Province Metallurgical Engineering Co.,Ltd., Jinan 250101,China; 2 China Construction Design International, Shanghai 200235, China)Abstract: Based on the vibrational parameters of trial runs on structure layer of coke house vibrating screen in 3000m3 blast furnace, the vibrational characteristics of structure layer were analyzed and studied. Reinforcement schemes were compared and chosen. The requirements and structure measures for anti vibration of structure layer were discussed.
Keywords: coke house vibrating screen;beam and plate vibration;disturbing force;vibration reduction and strengthening