- 摘 要
-
蔡賢輝 鄔瑞鋒 奚肖鳳 解明雨 沈全鋒 (大連理工大學(xué)工程力學(xué)系 116023)張前國 李慶剛 (遼寧省建筑設(shè)計(jì)研究院 沈陽 110005)[提要] 組合砌體剪力墻是由多種不同力學(xué)特性的材料復(fù)合而成的結(jié)構(gòu)構(gòu)件,其承彎能力的計(jì)算比較復(fù)雜。從各組成材料的本構(gòu)關(guān)系出發(fā),并借助平截面假定,給出了砌體材料和混凝土材料的匹配關(guān)系,推導(dǎo)了該類剪力墻在兩種極限狀態(tài)下的承彎能力,同時(shí)指出這兩種極限狀態(tài)的界限受壓區(qū)高度。用本文公式計(jì)算的結(jié)果與彈塑性有限元及試驗(yàn)結(jié)果相比具有相當(dāng)好的精度。
[關(guān)鍵詞] 組合砌體剪力墻 抗彎承載力 匹配關(guān)系 界限受壓區(qū)高度The composite masonry shear wall is structured by several materials of different mechanical characteristics and its bending bearing capacity is complicated to estimate. Based on the constitutional relationship of the materials and the assumption of cross section keep plane, the material match between concrete and masonry and the bending bearing capacity of two different kinds of limit state are given. Meanwhile, the critical compressive height of the two limit states are pointed out here. The comparisons between the results of proposed formulas and elastic-plastic FEM analysis and test results show that the proposed formulas have acceptable accuracy.
Keywords: composite masonry shear wall; bending bearing capacity; match relationship; critical com-
pressive height