- 摘 要
-
毛煒烽1 肖 巖1,2 李 賢1 郭玉榮1
(1 湖南大學(xué)土木工程學(xué)院 長沙 410082;2 美國南加州大學(xué)土木工程系 洛杉磯 CA9008925311)
[提要] 設(shè)計了三組高強、足尺的螺栓端板連接的鋼梁鋼筋混凝土柱組合節(jié)點試件,完成了其在低周反復(fù)荷載作用下的受力性能試驗研究。試驗結(jié)果表明,該新型組合節(jié)點具有優(yōu)良的抗震性能和優(yōu)越的施工性,在高強螺栓端板連接設(shè)計中應(yīng)適當加大螺栓承載力的安全儲備。
[關(guān)鍵詞]
高強螺栓 端板 組合節(jié)點 抗震性能
Experimental Research on Endplate Bolted Connection with Steel Beam and Reinforced Concrete Column/Mao Weifeng1, Xiao Yan1,2,Li Xian1,Guo Yurong1(1 College of Civil Engineering,Hunan University,Changsha 410082,China; 2 Dept.of Civil Engineering of Southern California,CA90089,USA)
Abstract:A new type of endplate bolted connection with steel beam and reinforced concrete column is investigated,and three fullscale connections were tested under simulated seismic loading.Experimental results show that this new type of composite connection has satisfactory seismic performance with excellent ductility as well as good energy dissipation capability.
Keywords:posttensioned high strength bolts; endplate; composite connections; seismic behavior