陳 瑜1,鄭立煌1,黃寶清1,裴茂祥2,馬 越2
(1 建研科技股份有限公司,北京100013; 2 中國民航機場建設(shè)集團公司,北京100013)[摘要] 武漢天河機場新航站樓設(shè)計中,采用后張有(無)粘結(jié)預(yù)應(yīng)力混凝土技術(shù)有效解決了主體結(jié)構(gòu)大空間、大跨度、相鄰變跨度、大跨度懸挑和超大平面未設(shè)溫度變形縫等關(guān)鍵技術(shù)問題,介紹了其預(yù)應(yīng)力混凝土梁的計算分析和配筋設(shè)計,以及無粘結(jié)預(yù)應(yīng)力地下室頂板的設(shè)計。為國內(nèi)類似規(guī)模建筑的樓面設(shè)計提供了成功經(jīng)驗。
[關(guān)鍵詞] 有(無)粘結(jié)預(yù)應(yīng)力;大跨度懸挑;超大平面;溫度變形縫Prestressed concrete structure design of new navigation building in extension project of Wuhan Tianhe airport
Chen Yu1, Zheng Lihuang1, Huang Baoqing1, Pei Maoxiang2, Ma Yue2
(l CABR Technology Co., Ltd., Beijing 100013, China; 2 CCAC Co., Ltd., Beijing 100013, China)Abstract: During the design of new navigation building in extension project of Wuhan Tianhe airport, adhesive (unbonded) prestress technology is adopted to efficiently solve critical technology difficulties as large space of main structure, long span, adjacent variable spans, superlongspan cantilever and super plane without expansion joints. The calculation analysis of the prestress concrete beam, and the design of the reirforcement and the unbonded prestress basement roof are presented, which affords succestful experience for floor design of domestic similar scale building.