- 摘 要
-
萬(wàn)墨林?。ㄖ袊?guó)建筑科學(xué)研究院 北京 100013)
[提要]《混凝土結(jié)構(gòu)后錨固技術(shù)規(guī)程》(JGJ145-2004)是我國(guó)第一本有關(guān)后錨固連接技術(shù)的設(shè)計(jì)施工規(guī)程,包括后錨固連接分類及適用范圍、設(shè)計(jì)計(jì)算方法、構(gòu)造措施及施工要點(diǎn)等。后錨固技術(shù)是現(xiàn)代房屋裝修、設(shè)備安裝、舊房改造及工程結(jié)構(gòu)加固等的專用技術(shù)。
[關(guān)鍵詞] 后錨固 錨栓 基材 被連接件 破壞模式 錨固承載力Technical specification of post-anchoring used in concrete(JGJ145-2004) is the technical specification firstly published in China for connections concrete and other members with anchors in concrete. The contents include the connection types,application scope,calculation method,construction and so on. The technique is a special technique used in the engineerings of house decoration, equipment installation,reconstruction and reinforcement etc.
Keywords: post-anchoring; bolt; connection member; destroy model; anchoring bearing capacity參 考 文 獻(xiàn)
1.Guideline for European Technical Approval of Anchors( Metal Anchors) for Use in Concrete (ETAG). European Organisation for Technical Approvals, B-1050 Brussels.
2.Eligehausen.Connections between steel and concrete. Volume工,Ⅱ,RILFM Publications S A. R. L,The Publishing Company of RILEM
3.Bulletin D'information N0216, Fastenings to concrete and masonry structures. July 1994, CEB Committee Euro-International Du Beton.
4.Eligehausen, Malle'e, Rehm. Befestigungstechnik. Sonderdruck ausdem Beton-Kalender, 1997.
5.萬(wàn)墨林等.建筑錨栓承載力測(cè)評(píng).中國(guó)建筑科學(xué)研究院,2000.