884aa四虎影成人精品,99久久国产综合精品女图图等你,97在线观看永久免费视频,久久精品国产精品亚洲38,ⅵdeodesetv性欧美

您現(xiàn)在的位置:建筑結(jié)構(gòu)>> 期 刊>> 2022年>> 第06期>>正文內(nèi)容
預(yù)制混凝土疊合樓板新型連接構(gòu)造的力學(xué)性能研究?
張 敏1,2, 秦 穩(wěn)1,2, 盧 旦3, 陳宜虎4, 潘 丹1,2
摘 要

(1 桂林理工大學(xué)土木與建筑工程學(xué)院, 桂林 541004; 2 廣西巖土力學(xué)與工程重點(diǎn)實(shí)驗室, 桂林 541004;3 華東建筑設(shè)計研究院有限公司, 上海 200002; 4 賀州學(xué)院建筑工程學(xué)院, 賀州 542899)

摘要: 對四個采用不同連接構(gòu)造裝配制作的預(yù)制混凝土疊合板試件進(jìn)行單調(diào)靜力加載試驗,研究試件的破壞形態(tài)、承載極限等力學(xué)性能,并進(jìn)行有限元分析。 結(jié)果表明:各試件均經(jīng)歷彈性階段、彈塑性階段及破壞階段,屬于延性破壞,試件承載力均達(dá)到設(shè)計預(yù)期,與現(xiàn)澆試件理論計算的承載力相當(dāng);所有試件的破壞位置均出現(xiàn)在連接區(qū)域之外的斷面,并非在跨中位置,實(shí)現(xiàn)了節(jié)點(diǎn)處“強(qiáng)連接”的目標(biāo);鋼筋 U 型連接以及側(cè)面開槽封閉環(huán)筋搭接連接構(gòu)造的鋼筋均能實(shí)現(xiàn)有效錨固;疊合板的預(yù)制層可與后澆層協(xié)同工作。

關(guān)鍵詞: 預(yù)制混凝土疊合樓板; 新型連接; 靜力加載試驗; 數(shù)值分析; 破壞形態(tài)

中圖分類號:TU375. 2,TU317. 1 文獻(xiàn)標(biāo)志碼:A 文章編號:1002 ̄848X(2022)06 ̄0026 ̄06

DOI:10. 19701 / j.jzjg.20200782

Research on mechanical properties of prefabricated concrete composite floor with new connection

ZHANG Min1,2, QIN Wen1,2, LU Dan3, CHEN Yihu4, PAN Dan1,2

(1 College of Civil Engineering and Architecture, Guilin University of Technology, Guilin 541004, China;2 Guangxi Key Laboratory of Rock and Soil Mechanics and Engineering, Guilin 541004, China; 3 East China ArchitecturalDesign & Research Institute Co., Ltd., Shanghai 200002, China; 4 College of Civil Engineering and Architecture,Hezhou University, Hezhou 542899, China)

Abstract: The monotonic static loading test was carried out on four prefabricated concrete composite slab specimensassembled with different connection structures, and the mechanical properties such as the failure form and bearing limit ofthe specimen were studied and finite element analysis was carried out. The results show that each specimen has undergonean elastic stage, an elastoplastic stage and a failure stage, which belong to the ductile failure. The bearing capacity of thespecimen has reached the design expectation, which is equivalent to the theoretical calculation of the cast ̄in ̄placespecimen. The damage position of all specimens appear on the cross section outside the connection area, not at themid ̄span position, achieve the goal of “strong connection” at the node. The steel bar U ̄shaped connection and the steel barwith the side slotted closed ring bar lap connection structure can achieve effective anchorage. The prefabricated layer of thelaminated board can work with the post ̄cast layer.

Keywords:prefabricated concrete composite floor; new connection; static loading test; numerical analysis; failure mode

∗國家重點(diǎn)研發(fā)計劃(2016YFC0701902 ̄4),廣西自然科學(xué)基金資助項目(2018GXNSFAA050145)。

第一作者:張敏,博士,教授,碩士生導(dǎo)師,一級注冊結(jié)構(gòu)工程師,主要從事裝配式建筑研究,Email: emailzm@ 126.com。

[引用本文] 張敏,秦穩(wěn),盧旦,等. 預(yù)制混凝土疊合樓板新型連接構(gòu)造的力學(xué)性能研究[ J]. 建筑結(jié)構(gòu), 2022, 52(6):26 ̄31,130. ZHANG Min, QIN Wen, LU Dan, et al. Research on mechanical properties of prefabricated concretecomposite floor with new connection[J]. Building Structure, 2022, 52(6):26 ̄31,130.

下載地址

    你還沒注冊?或者沒有登錄?這篇論文要求至少是本站的注冊會員才能閱讀!

    如果你還沒注冊,請趕緊點(diǎn)此注冊吧!