摘要: 使用多質(zhì)點(diǎn)模型對(duì)中低層鋼筋混凝土建筑和鋼結(jié)構(gòu)建筑進(jìn)行了地震時(shí)程反應(yīng)分析. 結(jié)果表明,由響應(yīng)值確定的地震等級(jí)與由“簡(jiǎn)易法”評(píng)價(jià)的地震等級(jí)相當(dāng).
關(guān)鍵詞: 性能設(shè)計(jì); 靜力設(shè)計(jì); 中低層建筑; 抗震性能等級(jí); 層間位移角; 時(shí)程反應(yīng)分析; 多質(zhì)點(diǎn)模型
中圖分類(lèi)號(hào):TU318+. 4 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):1002-848X(2023)04-0040-03
DOI:10. 19701 / j. jzjg. JSCA2311
Commentary to the 2021 edition of the JSCA performance-based seismic design manaual part 8:
verification of judgment criteria by seismic response analysis of multi mass model
Miwa SADAMOTO
(Nikken Sekkei Ltd. , Tokyo 102-8117, Japan)
Abstract:Time history response analysis was conducted using a multi mass model assuming low-rise RC an S buildings,and it was shown that the seismic grade determined from the response values was equivalent to the seismic grade determinedby the " simplified method" .
Keywords:performance-based design; static design; low or middle-rise building; seismic performance level; story drift;time history analysis; multi-degree-of-freedom system
作者簡(jiǎn)介:貞許美和,工程部結(jié)構(gòu)設(shè)計(jì)群總監(jiān),主要從事結(jié)構(gòu)設(shè)計(jì).
[引用本文] 貞許美和. 2021 年版日本抗震性能化設(shè)計(jì)手冊(cè)解讀 8:基于多質(zhì)點(diǎn)模型時(shí)程反應(yīng)分析對(duì)判定標(biāo)準(zhǔn)的驗(yàn)證[J]. 建筑結(jié)構(gòu),2023,53(4):40-42. Miwa SADAMOTO. Commentary to the 2021 edition of the JSCA performancebased seismic design manaual part 8:verification of judgment criteria by seismic response analysis of multi mass model[J].Building Structure,2023,53(4):40-42.