波紋鋼板組合框架節(jié)點抗震性能試驗研究
鄒 昀1, 繆嘉煒1, 王城泉1, 時建新1, 陳 明2, 吳藝超2
摘 要

(1 江南大學環(huán)境與土木工程學院, 無錫 214122; 2 上海歐本鋼結(jié)構(gòu)有限公司, 上海 200127)

摘要: 基于波紋鋼-鋼管混凝土組合柱與 U 形外包波紋鋼-混凝土組合梁,以“強節(jié)點弱構(gòu)件”的設(shè)計原則提出了一種施工便捷、傳力明確的節(jié)點連接方式. 對中節(jié)點試件進行了低周往復(fù)加載下的擬靜力試驗,分析了節(jié)點的破壞形態(tài)、滯回曲線、耗能能力、延性、梁端塑性鉸區(qū)以及節(jié)點核心區(qū)關(guān)鍵部位鋼材的應(yīng)變變化,通過有限元軟件對節(jié)點進行模擬,并與試驗進行對比發(fā)現(xiàn)二者吻合較好. 研究表明:試件最終破壞的位置為梁端理想塑性鉸區(qū),節(jié)點核心區(qū)域未發(fā)生明顯破壞,實現(xiàn)了塑性鉸的外移;試件滯回曲線飽滿,等效黏滯阻尼系數(shù)為 0. 206,延性系數(shù)為 3. 67,說明試件具有較好的耗能能力以及延性. 節(jié)點域鋼材各位置應(yīng)變分布均勻,傳力效果良好,節(jié)點核心區(qū)未屈服,梁下翼緣塑性鉸區(qū)應(yīng)變達到屈服應(yīng)變,節(jié)點工作性能良好,能有效傳遞彎矩以及剪力.

關(guān)鍵詞: 波紋鋼-鋼管混凝土組合柱;U 形外包波紋鋼-混凝土組合梁; 節(jié)點抗震性能; 擬靜力試驗

中圖分類號:TU398 文獻標志碼:A 文章編號:1002-848X(2023)05-0136-005

DOI:10. 19701 / j. jzjg. 20210074

Seismic performance test research on composite frame joint using corrugated steel plates

ZOU Yun1, MIAO Jiawei1, WANG Chengquan1, SHI Jianxin1, CHEN Ming2, WU Yichao2

(1 School of Environment and Civil Engineering, Jiangnan University, Wuxi 214122, China;2 Shanghai Open Steel Structure Co. , Ltd. , Shanghai 200127, China)

Abstract: Based on the corrugated steel-tubular composite column infilled with concrete and reinforced concrete beam withU shape corrugated steel webs developed, a connection method with convenient construction and clear force transmissionwas proposed based on the design principle of " strong joints and weak components" . A pseudo-static test under low-cyclereciprocating loading of the middle joint specimen was carried out, the failure form, hysteresis curve, energy dissipationcapacity, ductility, plastic hinge area of the beam end and the strain change of the key parts of the core area of the jointswere analyzed. Numerical simulation for joint was carried out through finite element software, which is consistent with theexperimental phenomenon. The research results show that the final failure position of the specimen is the plastic hinge areaat the beam end, the core area of the joint has no obvious damage, the plastic hinge is moved outward; the hysteresis curveof the specimen is full, and the equivalent viscous damping coefficient of the specimen is 0. 206 and the ductility coefficientis 3. 67, which show that the specimen has good energy consumption and ductility. The steel strains in the joint area areevenly distributed in various positions, and the force transmission effect is good. The core area of the joint is not yielded,and the strain of the lower flange of the plastic hinge area of the beam end reaches the yield strain. The joint workperformance is good, and the bending moment and shear force can be effectively transmitted.

Keywords:corrugated steel-tubular composite column infilled with concrete; reinforced concrete beam with U shapecorrugated steel plate; joint seismic performance; pseudo-static test

∗2018 年江蘇省科技廳社會發(fā)展面上項目(BE2018625),江蘇省自然科學基金資助項目(BK20180623),2016 年江蘇省建筑產(chǎn)業(yè)現(xiàn)代化示范基地項目.

第一作者:鄒昀,博士,教授,碩士生導師,主要從事鋼-混凝土組合結(jié)構(gòu)研究,Email:zouyun_22@ 126. com.

[引用本文] 鄒昀,繆嘉煒,王城泉,等. 波紋鋼板組合框架節(jié)點抗震性能試驗研究[ J]. 建筑結(jié)構(gòu),2023,53(5):136-140,118. ZOU Yun,MIAO Jiawei,WANG Chengquan,et al. Seismic performance test research on composite framejoint using corrugated steel plates [J]. Building Structure,2023,53(5):136-140,118.