摘要: 既有建筑為原北京市商標(biāo)廠印刷車間,改造后功能為小學(xué)校教學(xué)樓,采用黏滯阻尼器進(jìn)行消能減震加固.對(duì)與消能減震部件相連的構(gòu)件進(jìn)行加固,其他部位僅需要少量加固即可滿足抗震性能要求,減少了對(duì)結(jié)構(gòu)構(gòu)件的直接加固的工作量. 采用 SAP2000 軟件對(duì)結(jié)構(gòu)進(jìn)行小震下 FNA(快速非線性)時(shí)程分析,為校核計(jì)算附加阻尼比的準(zhǔn)確性,對(duì)比了一周能量比法和模態(tài)耗能比法的計(jì)算結(jié)果. 采用 SUASAGE 軟件對(duì)結(jié)構(gòu)進(jìn)行大震彈塑性時(shí)程分析,驗(yàn)算加固后結(jié)構(gòu)抗震性能,并對(duì)子結(jié)構(gòu)進(jìn)行設(shè)計(jì). 分析結(jié)果表明,設(shè)置黏滯阻尼器對(duì)既有建筑進(jìn)行消能減震加固改造,黏滯阻尼器耗能作用明顯,避免了大范圍的結(jié)構(gòu)構(gòu)件加固工作;應(yīng)采用不同計(jì)算方法復(fù)核,保證附加阻尼比計(jì)算的準(zhǔn)確性.
關(guān)鍵詞: 既有建筑改造; 消能減震加固; 黏滯阻尼器; 附加阻尼比
中圖分類號(hào):TU318 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):1002-848X(2023)08-0090-05
DOI:10. 19701 / j. jzjg. 20220477
Application of energy dissipation reinforcement technology in an existing building transformation project
GUAN Yu
(Beijing Institute of Architectural Design, Beijing 100062, China)
Abstract: The existing building is the printing workshop of Beijing Trademark Factory. After the reconstruction, thefunction is the primary school teaching building. The fluid viscous damper was used for energy dissipation reinforcement.The members connected to the energy dissipation and damping components were reinforced,and the other parts only need asmall amount of reinforcement to meet the seismic performance requirements, reducing the workload of direct reinforcementof structural members. SAP2000 software was used to carry out FNA (fast nonlinear analysis) time-history analysis of thestructure under frequent earthquakes. In order to check the accuracy of the calculation of the additional damping ratio, thecalculation results of the one-cycle energy ratio method and the modal energy ratio method were compared. SUASAGEsoftware was used to carry out rare occurrence earthquake elastic-plastic time-history analysis of the structure. The seismicperformance of the strengthened structure was checked, and the substructure was designed. The analysis results show thatthe fluid viscous damper has an obvious effect on energy dissipation of existing buildings, which avoids a large range ofstructural member reinforcement. Different calculation methods should be adopted for recheck to ensure the accuracy of thecalculation of additional damping ratio.
Keywords: existing building transformation; energy dissipation reinforcement; fluid viscous damper; additionaldamping ratio
作者簡介:關(guān)宇,碩士,高級(jí)工程師,一級(jí)注冊(cè)結(jié)構(gòu)工程師,主要從事建筑工程結(jié)構(gòu)設(shè)計(jì),Email:612624@ qq. com.
[引用本文] 關(guān)宇. 消能減震加固技術(shù)在既有建筑改造工程中的應(yīng)用[ J]. 建筑結(jié)構(gòu),2023,53(8):90-94. GUANYu. Application of energy dissipation reinforcement technology in an existing building transformation project[J]. BuildingStructure,2023,53(8):90-94.
- 下載地址
-
你還沒注冊(cè)?或者沒有登錄?這篇論文要求至少是本站的注冊(cè)會(huì)員才能閱讀!
如果你還沒注冊(cè),請(qǐng)趕緊點(diǎn)此注冊(cè)吧!
如果你已經(jīng)注冊(cè)但還沒登錄,請(qǐng)趕緊點(diǎn)此登錄吧!