- 摘 要
-
(1 河南工業(yè)大學(xué)土木工程學(xué)院, 鄭州 450001; 2 中建中原建筑設(shè)計(jì)院有限公司, 鄭州 450004)
摘要: 為研究帶預(yù)制混凝土(PC)填充墻的裝配式聯(lián)肢剪力墻抗側(cè)剛度與水平承載力計(jì)算方法,完成了 1 個(gè)無填充墻和 2 個(gè)帶 PC 填充墻試件的低周往復(fù)荷載試驗(yàn),考察了 PC 填充墻對(duì)裝配式聯(lián)肢剪力墻抗側(cè)剛度和水平承載力的影響,在試驗(yàn)基礎(chǔ)上建立了結(jié)構(gòu)簡化分析模型,提出了聯(lián)肢剪力墻抗側(cè)剛度和水平承載力計(jì)算方法. 結(jié)果表明:帶 PC 填充墻的裝配式聯(lián)肢剪力墻試件整體性較好,PC 填充墻的存在可提高試件的抗側(cè)剛度和水平承載力;PC 填充墻與聯(lián)肢剪力墻的連接形式對(duì)試件的抗側(cè)剛度和水平承載力有較大影響;基于連續(xù)化計(jì)算方法提出的帶 PC 填充墻的裝配式聯(lián)肢剪力墻抗側(cè)剛度和水平承載力計(jì)算方法,計(jì)算結(jié)果與試驗(yàn)值吻合良好.
關(guān)鍵詞: 裝配式聯(lián)肢剪力墻; 預(yù)制混凝土填充墻; 柔性連接; 剛性連接; 抗側(cè)剛度; 水平承載力
中圖分類號(hào):TU399、TU317+. 1 文獻(xiàn)標(biāo)志碼:A 文章編號(hào):1002-848X(2023)11-0054-07
DOI:10. 19701 / j. jzjg. LS210024
Study on calculation method of lateral stiffness and horizontal bearing capacity of prefabricated coupled shear wall with PC infill wall
PANG Rui1, WANG Wenjie1, LIU Xiaoyi1, ZHANG Haidong2, DIAKHATE Adama1
(1 School of Civil Engineering, Henan University of Technology, Zhengzhou 450001, China;2 CSCEC Zhongyuan Architectural Design Institute Co. , Ltd. , Zhengzhou 450004, China)
Abstract: To study the calculation method of lateral stiffness and horizontal bearing capacity of prefabricated coupled shearwall with precast concrete (PC) infill wall, the low-cyclic loads tests of one specimen without infill wall and two specimenswith PC infill wall were completed, and the effects of PC infill wall on lateral stiffness and horizontal bearing capacity ofprefabricated coupled shear wall were investigated. Based on the tests, a simplified structural analysis model wasinvestigated. The calculation method of lateral stiffness and horizontal bearing capacity of coupled shear wall was proposed.The results show that the integrity of the prefabricated coupled shear wall with PC infill wall is good, the existence of PCinfill wall can improve the lateral stiffness and horizontal bearing capacity of the specimen. The connection form of PC infillwall and coupled shear wall has a great influence on the lateral stiffness and horizontal bearing capacity of the specimen;Based on the continuous calculation method, the anti-side stiffness and horizontal bearing capacity of the prefabricatedcoupled shear wall with PC infill wall is proposed by the continuous calculation method, and the calculation results are goodwith the experimental value.
Keywords:prefabricated coupled shear wall; precast concrete infill wall; flexible connection; rigid connection; lateralstiffness; horizontal bearing capacity
∗國家自然科學(xué)基金(51778214),中原青年拔尖人才支持項(xiàng)目(ZYQR201912170),河南省屬高?;究蒲袠I(yè)務(wù)專項(xiàng)基金(2017RCJH04).
第一作者:龐瑞,博士,教授,博士生導(dǎo)師,從事裝配式混凝土結(jié)構(gòu)研究,Email: seupangrui@ 163. com.
[引用本文] 龐瑞,王文杰,劉曉怡,等. 帶 PC 填充墻的裝配式聯(lián)肢剪力墻抗側(cè)剛度與水平承載力計(jì)算方法研究[J]. 建筑結(jié)構(gòu),2023,53(11):54-60,121. PANG Rui,WANG Wenjie,LIU Xiaoyi,et al. Study on calculation method oflateral stiffness and horizontal bearing capacity of prefabricated coupled shear wall with PC infill wall [ J]. BuildingStructure,2023,53(11):54-60,121.