[摘要]為達(dá)到建筑使用品質(zhì)及抗震性能的協(xié)調(diào)統(tǒng)一,在高烈度地區(qū)大底盤多塔高層建筑結(jié)構(gòu)采用層間隔震技術(shù)是一種有效的解決方案。通過對某大底盤多塔高層建筑的結(jié)構(gòu)方案比選分析,最終采用層間隔震技術(shù)方案,并對其地震反應(yīng)及抗震性能進(jìn)行了分析研究。結(jié)果表明:層間隔震技術(shù)整體減震效果良好,可以大幅減小地震反應(yīng),是提高結(jié)構(gòu)抗震安全性的有效手段;綜合考慮項目結(jié)構(gòu)特點(diǎn)、經(jīng)濟(jì)性及建筑品質(zhì)的提升,在高烈度區(qū)大底盤多塔結(jié)構(gòu)中采用層間隔震技術(shù)是一種優(yōu)選的實(shí)施方案;最后針對大底盤層間隔震技術(shù)的組合隔震方案、隔震支座附加彎矩、支座抗拉裝置等若干關(guān)鍵技術(shù)問題進(jìn)行討論,可為類似工程實(shí)踐提供參考。
[關(guān)鍵詞]高烈度地區(qū); 大底盤多塔結(jié)構(gòu); 高層建筑; 層間隔震技術(shù)
中圖分類號:TU352-1, TU973+.2文獻(xiàn)標(biāo)識碼:A文章編號:1002-848X(2020)10-0083-07
Structural scheme selection and design of an isolated high-rise building structure with a large chassis and multiple tower-layer in a high-intensity region
LIUFU Jun1,2, LIN Shaoming2,1, HUANG Zhonghai1,2, LI Shengyong1,2, XIE Congrui1,2, HUANG Yuangen1,2
(1 RBS Architecture Engineer Design Associate, Guangzhou 510170, China;2 RBS Partners S&T Co., Ltd., Guangzhou 510170, China)
Abstract:In order to achieve the harmonization of the quality of the building and the seismic performance, it is an effective solution to adopt the story isolation technique in the large chassis and multiple tower-layer high-rise building structure in high intensity region. Through the comparison and analysis of the structural schemes of a large chassis multiple tower-layer high-rise building, the ultimate seismic isolation scheme was adopted, and its seismic response and seismic performance were analyzed and studied. The results show that the overall seismic isolation effect of the story isolation technique is good, which can greatly reduce the seismic response, and is an effective means to improve the seismic safety of the structure; Considering the structural characteristics of the project, the improvement of the economy and the quality of the building, the use of story isolation technique in the large chassis multiple tower-layer structure in the high intensity region is an optimal scheme; Finally, several key technical issues such as the combined seismic isolation scheme of large chassis story isolation technique, the additional bending moment of the isolator, and the tensile device of the isolator were discussed, which can provide reference for similar engineering practices.
Keywords:high intensity region; large chassis and multiple tower-layer structure; high-rise building; story isolation technique
*廣州市科技計劃項目(201906010012),廣州市創(chuàng)新創(chuàng)業(yè)領(lǐng)軍團(tuán)隊項目(CYLJTD\|201608),廣州市科技計劃項目(201704020172)。
通訊作者:林紹明,博士,高級工程師, Email:linshaoming@gzrbs.com。
- 下載地址
-