884aa四虎影成人精品,99久久国产综合精品女图图等你,97在线观看永久免费视频,久久精品国产精品亚洲38,ⅵdeodesetv性欧美

您現(xiàn)在的位置:建筑結(jié)構(gòu)>> 期 刊>> 2019年>> 第17期>>正文內(nèi)容
歐美最新混凝土收縮徐變理論的數(shù)值對比及應(yīng)用
陳晉,丁晗,鄧嵐青,李喆
摘 要

(美國SOM建筑結(jié)構(gòu)事務(wù)所, 芝加哥 60604)

[摘要]對比了在超高層結(jié)構(gòu)分析中較常采用的CEB-FIP-90,fib MC2010以及GL2000模型收縮徐變理論在相同假設(shè)條件下的結(jié)果,有助于工程師了解歐美混凝土收縮徐變理論的最新發(fā)展方向。相較于國內(nèi)在工程中采用較多的CEB-FIP-90模型,GL2000以及fib MC2010模型已經(jīng)將混凝土徐變細(xì)分成基本徐變和干燥徐變。fib MC2010模型更進(jìn)一步將混凝土收縮細(xì)化成基本收縮及干燥收縮。以南寧某帶有外伸桁架的巨柱外框超高層地標(biāo)塔樓為例,按不同混凝土收縮徐變理論進(jìn)行非線性施工分析,對施工期間的豎向構(gòu)件的豎向補(bǔ)償提出建議,并預(yù)測了施工完畢后若干年的核心筒和巨柱的豎向變形、軸力隨時(shí)間的變化,以及與時(shí)間相關(guān)的樓板系統(tǒng)的傾斜變化趨勢。

[關(guān)鍵詞]超高層結(jié)構(gòu); 外伸桁架; CEB-FIP-90; fib MC2010; GL2000; 非線性施工分析; 施工補(bǔ)償; 豎向變形

中圖分類號:TU375文獻(xiàn)標(biāo)識碼:A文章編號:1002-848X(2019)17-0090-08

 

Numerical comparison and application of latest European and American creep and shrinkage theories

Chen Jin, Ding Han, Dane Rankin, Li Zhe

(Skidmore, Owings & Merrill LLP, Chicago 60604, U.S.A)

Abstract:The results of the concrete creep and shrinkage theories in CEB-FIP-90, fib MC2010 and GL2000 models, which were widely applied in super tall structural analysis, were compared under the same assumption conditions. This could help engineers to better understand the latest research directions of European and American concrete creep and shrinkage theories. Compared with the more commonly used CEBFIP-90 model in China, GL2000 model and fib MC2010 model differentiate the concrete creep into basic creep and drying creep. Furthermore, fib MC2010 model divides the concrete shrinkage into basic shrinkage and drying shrinkage. Taking a mega-frame super-tall landmark tower building in Nanning as an example, nonlinear construction sequence analysis was conducted based on different concrete shrinkage and creep theories. Suggestions were put forward for vertical compensation of vertical components during construction, and predicted the vertical deformation of corewall and mega-frame in several years after completion of construction, the change of axial force of corewall and mega-frame over time. And the inclination trend of floor system related to time was also predicted.

Keywords:super-tall building structure; outrigger truss; CEB-FIP-90; fib MC2010; GL2000; nonlinear construction sequence analysis; construction compensation; vertical deformation

 

作者簡介:陳晉,碩士,SOM結(jié)構(gòu)副總監(jiān),美國注冊結(jié)構(gòu)工程師,注冊職業(yè)工程師,Email: jin.chen@som.com。

下載地址

    你還沒注冊?或者沒有登錄?這篇論文要求至少是本站的注冊會員才能閱讀!

    如果你還沒注冊,請趕緊點(diǎn)此注冊吧!

    如果你已經(jīng)注冊但還沒登錄,請趕緊點(diǎn)此登錄吧!