不均勻溫度作用對廣州新客站主站房鋼結(jié)構(gòu)影響
高昂1,陳兆雄2,馮健2,盛平1
- 摘 要
-
(1 北京市建筑設(shè)計研究院, 北京 100045; 2 東南大學(xué)土木工程學(xué)院, 南京 210096)[摘要]廣州新客站屋頂為大跨度鋼結(jié)構(gòu),溫度作用是結(jié)構(gòu)設(shè)計的控制因素之一。采用Ecotect軟件,研究了廣州新客站各時刻不均勻溫度的分布。利用MIDAS軟件,分析了不均勻溫度作用對屋頂結(jié)構(gòu)的影響,并與整體均勻升溫作用對結(jié)構(gòu)的影響進(jìn)行了對比。結(jié)果表明,整體均勻升溫并非結(jié)構(gòu)設(shè)計的最不利工況,結(jié)構(gòu)設(shè)計需要考慮不均勻溫度作用的影響。[關(guān)鍵詞]廣州新客站;鋼結(jié)構(gòu);不均勻溫度;溫度作用Influences of non-uniform temperature action on steel structures of main building of New Guangzhou StationGao Ang1, Chen Zhaoxiong2,F(xiàn)eng Jian2, Sheng Ping1(1 Beijing Institute of Architectural Design, Beijing 100045, China; 2 School of Civil Eng., Southeast University, Nanjing 210096,China)Abstract:The roof structure of New Guangzhou Railway Station is a large-span structure, and the temperature action is one of controlling factors. Using software Ecotect, the distribution of non-uniform temperature is studied. Using software MIDAS, the influences of non-uniform temperature action are analyzed, and compared with those of uniform temperature action. The results show that uniform temperature action is not the most adverse combination, and the non-uniform temperature action should be considered for the structural design.Keywords:New Guangzhou Railway Station; steel structures; non-uniform temperature; temperature action作者簡介:高昂,碩士,工程師,Email:gaoangbiad@sina.com。參考文獻(xiàn)[1]盛平,柯長華,甄偉,等. 廣州新客站結(jié)構(gòu)總體設(shè)計[J]. 建筑結(jié)構(gòu),2009,39(12).[2]云朋. ECOTECT建筑環(huán)境設(shè)計教程[S].北京:中國建筑工業(yè)出版社,2007.[3]Ecotect技術(shù)手冊[M].