招商銀行深圳分行大廈主塔樓結(jié)構(gòu)抗震性能化設(shè)計(jì)
史杰,施泓,尹海鵬
摘 要
(中國(guó)建筑設(shè)計(jì)院有限公司,  北京 100044)

[摘要]招商銀行深圳分行大廈主塔樓結(jié)構(gòu)高度為160.2m,外框架存在兩次斜柱轉(zhuǎn)換,高位轉(zhuǎn)換以下采用鋼管混凝土柱、鋼梁框架+鋼筋混凝土核心筒,高位轉(zhuǎn)換以上采用鋼筋混凝土柱+鋼筋混凝土梁+鋼筋混凝土核心筒結(jié)構(gòu)體系。采用SATWE,MIDAS/Building軟件對(duì)結(jié)構(gòu)進(jìn)行了整體計(jì)算和彈性時(shí)程分析,采用ABAQUS軟件對(duì)結(jié)構(gòu)進(jìn)行了大震彈塑性分析;采用ANSYS軟件對(duì)斜柱轉(zhuǎn)換進(jìn)行了節(jié)點(diǎn)分析,對(duì)底部躍層柱進(jìn)行了屈曲分析。計(jì)算結(jié)果表明,結(jié)構(gòu)各項(xiàng)指標(biāo)均滿足規(guī)范相關(guān)要求,最后通過概念設(shè)計(jì)對(duì)關(guān)鍵和重要構(gòu)件作了適當(dāng)加強(qiáng),在構(gòu)造措施方面亦作了相應(yīng)處理,整體結(jié)構(gòu)滿足小震不壞,中震下主要構(gòu)件不屈服、震后可以修復(fù),大震不倒塌的抗震設(shè)防目標(biāo)。
[關(guān)鍵詞]招商銀行深圳分行大廈; 斜柱轉(zhuǎn)換; 鋼管混凝土柱; 躍層柱
中圖分類號(hào):TU318      文獻(xiàn)標(biāo)識(shí)碼:A      文章編號(hào):1002-848X(2016)09-0019-06

Performance-based seismic design for the main tower of China Merchants Bank (Shenzhen Branch) mansion
Shi Jie, Shi Hong, Yin Haipeng
(China Architecture Design Group, Beijing 100044, China)
 
Abstract: The main tower of China Merchants Bank (Shenzhen Branch) mansion has 160.2m structural height featured by two inclined column transfers in the exterior frame. Concrete filled steel tubular columns, steel beams and RC corewall structural system is adopted under the high-level transfer. Above the high-level transfer, RC columns, RC beams and RC corewall structural system is adopted. Programs of SATWE and MIDAS/Building were used for the integral calculation and elastic time-history analysis on the structure. ABAQUS program was adopted to conduct elasto-plastic analysis under the rare earthquake. Software ANSYS was used to conduct joint analysis on inclined column transfer and buckling analysis on the skip-floor columns. The calculation results show that all the indices of the structure can meet the relevant specification requirements. Finally, key and important elements were strengthened via concept design. Some structural details were adopted to make sure that the structure meets the seismic fortification goals of"overall structure is not damaged under the frequent earthquake, main components are not yielding and repairable after the earthquake, and overall structure is not collapsed".
Keywords: China Merchants Bank (Shenzhen Branch) mansion; inclined column transfer; concrete filled steel tubular column; skip-floor column