重慶華潤萬象城地下室設計方案的選型比較
劉杰,陳德良,王浩科
- 摘 要
-
(成都基準方中建筑設計有限公司,成都 610017)[摘要] 當前建筑大多帶有大體量的地下室,而地下室的設計方案通常在初步設計階段就需要作出比較。本文結合工程中地下室較為常用的結構形式(井字樓蓋、無梁樓蓋、預應力無梁樓蓋)從結構的受力性能和經(jīng)濟性能上做了比較分析,得出了可供借鑒的結論,并對不同樓蓋形式的適用情況給出了建議。[關鍵詞] 地下室;井字樓蓋;無梁樓蓋;預應力無梁樓蓋中國分類號:TU46 文獻標識碼:A 文章編號:1002-848X(2013)S2-0046-04Selection comparison on basement of Chongqing CRLL MixCLiu Jie, Chen Deliang, Wang Haoke(JZFZ Architectural Design Co., Ltd., Chengdu 610017, China)Abstract: Currently, more and more architectures are built with a large volume of the basement. At the stage of preliminary design phase the basement design scheme should make comparison .The commonly used structure forms (pigsty floor; beamless floor; prestressed flat slab) were analyzed and compared from the mechanical and economical performance. The conclusion can be used for reference, and the suggestions of the applicable condition of different structure are given.Keywords: basement; pigsty floor; beamless floor; prestressed flat slab