- 摘 要
-
(1 中國建筑設(shè)計研究院,北京 100044;2 西安建筑科技大學(xué),西安 710055;3 西北電力設(shè)計院, 西安 710075)
[摘要]基于混凝土損傷塑性模型和直接積分算法對一大型火電廠主廠房結(jié)構(gòu)進(jìn)行精細(xì)的動力彈塑性分析,研究主廠房結(jié)構(gòu)在地震過程中的變形性能、剛度退化規(guī)律和薄弱位置分布,給出主廠房結(jié)構(gòu)整體彈塑性性能的量化指標(biāo);研究錯層處構(gòu)件和帶“強梁約束”剪力墻等典型構(gòu)件的破壞特征;并將動力彈塑性分析結(jié)果與縮尺比為1∶7的擬動力試驗結(jié)果進(jìn)行對比。動力彈塑性分析結(jié)果與試驗結(jié)果吻合良好,驗證了動力彈塑性分析的準(zhǔn)確性與可行性。
[關(guān)鍵詞]動力彈塑性分析; 精細(xì)有限元分析; 火電廠; 主廠房
中圖分類號:TU271.1,TU398 文獻(xiàn)標(biāo)識碼:A 文章編號:1002-848X(2014)18-0063-05
Application of dynamic elastic-plastic analysis in the main plant structure of a large heat-engine plant
Zeng Jinsheng1, Bai Guoliang2, Liu Lin2, Li Hongxing3
(1 China Architecture Design & Research Group, Beijing 100044, China; 2 Xi′an University of Architecture and Technology, Xi′an 710055, China; 3 Northwest Electric Power Design Institute, Xi′an 710075, China)
Abstract: Based on the concrete damage plastic model and direct integral algorithm, the refined dynamic elastic-plastic analysis was carried out for the main plant structure of a large heat engine plant. The deformation performance, the stiffness degradation regularity and the weak position distributions of the main plant structure were studied, and the quantitative indicators for integral elastic-plastic performance of the main plant structure were given. The failure patterns of typical members as staggered members and the shear wall with big restrained beams were studied. The dynamic elastic-plastic analysis results were compared with the results of the 1∶7 scaled pseudo-dynamic test. The dynamic elastic-plastic analysis results agree well with the test results, which verifies the accuracy and feasibility of the dynamic elastic-plastic analysis.
Keywords: dynamic elastic-plastic analysis; refined finite element analysis; heat-engine plant; main plant
作者簡介:曾金盛,碩士,工程師,Email:zengjs@cadg.cn。
參考文獻(xiàn)
[1]汪大綏, 周建龍, 王建, 等. 建筑結(jié)構(gòu)非線性時程分析進(jìn)展[J]. 建筑結(jié)構(gòu), 2006, 36(6):84-87.
[2]李承銘, 李志山, 王國儉. 混凝土梁柱構(gòu)件基于截面纖維模型的彈塑性分析[J]. 建筑結(jié)構(gòu), 2007, 37(12):33-35.
[3]陸新征, 葉列平, 繆志偉. 建筑抗震彈塑性分析[M]. 北京: 中國建筑工業(yè)出版社, 2009.
[4]莊茁, 張帆, 岑松,等. ABAQUS非線性有限元分析與實例[M]. 北京: 科學(xué)出版社, 2005
[5]Dassault Systemes Simulia Corp. Abaqus6-10 theory manual [M]. USA, 2010.